The AURA One is HyperbaricO2Care’s flagship single-person mild hyperbaric oxygen chamber, engineered for safe and comfortable home oxygen therapy. With adjustable pressure from 1.1 to 1.7 atm and an oxygen concentration of ≥80%, the AURA One delivers consistent therapeutic oxygen enrichment for recovery, relaxation, and daily wellness. Designed with a low-entry door, quiet operation, and a smart touchscreen panel, it is the ideal hyperbaric oxygen solution for personal home use, senior wellness programs, and rehabilitation support.
Product Specifications
- Product Name:AURA One
- Size: 1800*1000*1850mm
- Weight: 800 kg
- User Capacity: 1person
- Chamber Volume:3.3 m³
- Oxygen Concentration: ≥ 80%
- Pressurization Method: Air Pressurization
- Pressurization/Depressurization Duration: 5 - 25 minutes
- Standard Model: 1.1 - 1.3 atm (Adjustable)
- High-end Model: 1.1 - 1.7 atm (Adjustable)
Product Details
Easy-Access Door Design
Intelligent Control Panel
Ambient Lighting
Emergency Call Device
Pressure Relief Valve Device
Air Conditioning System
Product Advantages
4G Emergency Call, Smoke Monitoring, Automatic/Manual Fire Suppression Sprinkler, and Triple Pressure Relief Valves
4-5mm Aviation Steel + Fully Welded Explosion-Proof PC Door
Self-Developed High-Efficiency Hyperbaric Oxygen Generation System
Gree Explosion-Proof Dedicated Chilled-Water Air Conditioning System
Equipment Operating Noise ≤ 50 dB
Multi-Stage Filtration System | Oxygen Concentration: 95.6% | Oxygen Outlet Pressure: 270 Kpa
Automatic/Manual Fire Sprinkler System
Automatic Mode: The sprinkler activates automatically when smoke or temperature sensors detect a fire.
Manual Mode: The system can be forced to activate via an on-site or remote manual button for emergency intervention or system testing.
4G Emergency Call
When the occupant is unable to operate the equipment directly (e.g., patient unconsciousness, cabin pressure loss), it sends a real-time distress signal via the 4G network to a monitoring center or medical staff.
Transmits real-time cabin data (e.g., oxygen concentration, pressure values) to facilitate remote diagnosis and rapid response.
Triple Pressure Relief Valve System
Mechanical Relief: Automatically opens to vent pressure when it exceeds the safe threshold (e.g., 2.5 ATA), preventing chamber rupture.
Automatic Relief: Utilizes electronic pressure sensors to control a solenoid valve for precise pressure release.
Manual Relief: Allows quick manual operation of the valve to force pressure release in emergencies (e.g., fire, occupant distress).