TITAN Duo Hero Section - Optimized
Dual-User Commercial Grade

TITAN Duo

Mild Hyperbaric Oxygen Chamber

The only hyperbaric chamber engineered for two simultaneous users — built for clinics and recovery centers that cannot afford downtime.

2
Users
simultaneously
8.2
Chamber
volume
≥90%
Oxygen
concentration
1.7 atm
Max
pressure
Technical Specifications

Built to the
highest clinical
standard

Every dimension, pressure range, and material is selected for commercial reliability — not just home use. The TITAN Duo is certified for facilities where uptime and safety are non-negotiable.

Product Name
TITAN Duo
User Capacity
2 persons
Dimensions
2080 × 1980 × 2000 mm
Weight
2,000 kg
Chamber Volume
8.2 m³
Oxygen Concentration
≥ 90%
Pressurization Method
Air Pressurization
Press/Depress Time
5 – 25 minutes
Standard Pressure
1.1 – 1.3 atm
High-End Pressure
1.1 – 1.7 atm
Noise Level
≤ 50 dB operating noise
Engineering

Built for
Daily Use

Door
Easy-Access Door Design
A highly sealed door structure maintains stable internal pressure, with simple open-and-close mechanics that require no technical training.
01 Easy-Access Door Design
02 Intelligent Control Panel
03 Ambient Lighting
04 Emergency Call Device
05 Triple Pressure Relief Valve
06 Air Conditioning System

Safety Systems

Four layers of protection,
always active

Fire

Automatic / Manual Fire Sprinkler

Activates automatically when smoke or temperature sensors detect a fire. Can also be triggered manually on-site or remotely — including for routine system testing. Designed for high-oxygen environments where standard sprinklers are insufficient.

4G

4G Emergency Call

When a user cannot operate the chamber directly — due to pressure loss or medical emergency — a real-time distress signal is sent via 4G to your monitoring center. Cabin data including oxygen concentration and pressure values travels with the alert.

PSV

Triple Pressure Relief Valves

Mechanical relief opens automatically above safe thresholds. Electronic sensors control a solenoid valve for precision release. Manual operation available for immediate forced venting in any emergency scenario.

Smk

Smoke Detection

Continuous real-time monitoring for combustion smoke from electrical faults or material overheating. Triggers both audible/visual alarm and the fire suppression system. Sensors are rated to resist false positives from high-temperature environments.

Other styles

Ready to bring the
TITAN Duo to your facility?

Our team will walk you through specifications, delivery, and installation — no commitment required.

Scroll to Top